HANNA Instruments HI 9142 Manual Calibration Dissolved Oxygen Meter
Order Information: |
|
HI 9142 is supplied with HI 76407/4 probe with 4 m (13’) cable, 2 spare membranes, HI 7041S electrolyte solution (30 mL), calibration screwdriver, batteries, instructions and rugged carrying case.
HI 9142/10 is supplied with everything above but substitutes a 10 m (32.8’) probe cable for the 4 m.
HI 9142/20 is supplied with everything above but substitutes a 20 m (65.6’) probe cable for the 4 m.
Description: |
|
The ever increasing demand for instant on-site analysis results has created a need for innovative and rugged portable, waterproof meters.
Field work can subject instrumentation to the inclemency of weather. Cold, rain, snow, dust and humidity can cause condensation to breech the housing. Once the housing has been compromised, the meter is susceptible to diminishing performance and life. The rugged, waterproof housing of the HI 9142 solves many of the problems of field use.
Calibration is performed with HI 7040 zero oxygen solution, while 100% calibration is done in air.
The polarographic probe (HI 76407/4) is accurate to 0.3 ppm and is supplied with a 4 m (13') cable that allows measurements to be taken even in hard to reach places.
Accessories: |
Solutions | |
---|---|
HI 7040L | Zero Oxygen Solution |
HI 7041S | Refilling Electrolyte Solution, 30 mL |
HI 7041M | Refilling Electrolyte Solution, 230 mL |
HI 7041L | Refilling Electrolyte Solution, 500 mL |
Accessories | |
HI 76407A/P | Membranes for DO Probes |
HI 721317 | Rugged Carrying Case for Portable, Waterproof and Printing Meters |
Probes | |
HI 76407/4 | Standard DO Probe, 4 m cable |
HI 76407/10 | Standard DO Probe, 10 m cable |
HI 76407/20 | Standard DO Probe, 20 m cable |
Specifications: |
|
Range | O2 | 0.0 to 19.9 mg/L (ppm) |
Temperature | -5.0 to 50.0ºC (32.0 to 122.0ºF) | |
Resolution | O2 | 0.1 mg/L (ppm) |
Temperature | 0.1°C (1ºF) | |
Accuracy (@20°C) | O2 | ±1.5% F.S. |
Temperature | ±0.2°C (±1ºF) (excluding probe error) | |
Calibration | manual, at one or two points (zero and slope) | |
Temperature Compensation |
automatic, 0 to 50°C (32 to 122°F) | |
Probe | HI 76407/4 polarographic DO probe with internal temperature sensor, DIN connector and 4 m (13’) cable | |
Battery Type / Life |
1.5V AAA (3) / approximately 1,000 hours of continuous use | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% | |
Dimensions | 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) | |
Weight | 300 g (10.6 oz.) |
MSDS: |
|
Click on the links below to download the Safety Data Sheet.
HI 7041S (HI 7041)
Downloads: |