Accessories Specifications Downloads
Description |
|
|
HI 98291-01L |
Multiparameter with HI7629829/4 pH/EC/DO Logging Probe, 4m cable.
|
HI 98293-01L |
Multiparameter with HI7629829/10 pH/EC/DO Logging Probe, 10m cable.
|
|
|
HI98292-01LT |
Multiparameter with HI7639829/4 pH/EC/DO/temp/Turbidity logging probe, 4m cable.
|
HI98294-01LT |
Multiparameter with HI7639829/10 pH/EC/DO/temp/Turbidity logging probe, 10m cable
|
Accessories | Back to Top |
Solutions | |
---|---|
HI 9829-16 |
Turbidity Calibration Solution, 0 FNU, 230 mL |
HI 9829-17 |
Turbidity Calibration Solution, 20 FNU, 230 mL |
HI 9829-18 |
Turbidity Calibration Solution, 200 FNU, 230 mL |
Accessories | |
HI 929829 |
PC Application Software |
HI 7698291 |
USB Cable, PC to Meter |
HI 76982910 |
USB cable, PC to Probe |
HI 710046 |
Lighter Cigarette Cable |
HI 7698290 |
Short Calibration Beaker |
HI 7698293 |
Long Calibration Beaker |
HI 7698294 |
Short Flow Cell |
HI 7698297 |
Long, Quick Release Flow Cell |
HI 7698295 |
Short Protective Shield |
HI 7698296 |
Long Protective Shield |
HI 920005 |
iButton® Tags |
HI 710140 |
Hard Carrying Case |
HI 710045 |
Power Supply Cable |
Reagents & Standards | |
HI 9829-10/11 |
ISE Standards Kit for HI 7609829-10, 10 Sachets ea. |
HI 9829-10 |
10 ppm Standard Sachets for HI 7609829-10 Ammonium ISE |
HI 9829-11 |
100 ppm Standard Sachet for HI 7609829-10 Ammonium ISE |
HI 9829-12/13 |
ISE Standards kit for HI 7609829-11 Chloride ISE |
HI 9829-12 |
10 ppm Standard Sachets for HI 7609829-11 Chloride ISE |
HI 9829-13 |
100 ppm Standard Sachet for HI 7609829-11 Chloride ISE |
HI 9829-14/15 |
ISE Standards for 7609829-12 Nitrate ISE |
HI 9829-14 |
10 ppm Standard Sachets for HI 7609829-12 Nitrate ISE |
HI 9829-15 |
100 ppm Standard Sachets for HI 7609829-12 Nitrate ISE |
Probes | |
HI 7609829-0 |
pH Sensor |
HI 7609829-1 |
pH/ORP Sensor |
HI 7609829-2 |
Dissolved Oxygen Sensor |
HI 7609829-3 |
Conductivity Sensor |
HI 7609829-4 |
Conductivity/Turbidity Sensor |
HI 7609829-10 |
Ammonium ISE |
HI 7609829-11 |
Chloride ISE |
HI 7609829-12 |
Nitrate ISE |
Quick Calibration Solutions | |
HI 9828-25 |
Quick Calibration Solution, 500 mL |
HI 9828-27 |
Quick Calibration Solution, 1 Gallon |
pH Calibration Solutions | |
HI 7004L |
4.01 pH Buffer Solution 1 x 500 mL bottle |
HI 7007L |
7.01 pH Buffer Solution 1 x 500 mL bottle |
HI 7010L |
10.01 pH Buffer Solution 1 x 500 mL bottle |
ORP Calibration Solutions | |
HI 7021L |
ORP Test Solution at (240 mV @ 25°C/77°F) 1 x 500 mL bottle |
HI 7022L |
ORP Test Solution at 470 mV @ 25°C/77°F) 1 x 500 mL bottle |
Dissolved Oxygen Solutions | |
HI 7040L |
Zero Oxygen Solution |
HI 7042S |
Electrolyte Solution for Galvanic Probes |
Conductivity Calibration Solutions | |
HI 7030L |
12880 µS/cm EC Solution, 500 mL Bottle |
HI 7031L |
1413 µS/cm EC Solution, 500 mL Bottle |
HI 7033L |
84 µS/cm EC Solution, 500 mL Bottle |
HI 7034L |
80000 µS/cm EC Solution, 500 mL Bottle |
HI 7035L |
111800 µS/cm EC Solution, 500 mL Bottle |
HI 7039L |
5000 µS/cm EC Solution, 500 mL Bottle |
Cleaning and Maintenance Solutions | |
HI 70300L |
Electrode Storage Solution 1 x 500 mL bottle |
HI 7061L |
General Purpose Cleaning Solution 1 x 500 mL bottle |
Specifications |
Range | pH/mV of pH input | 0.00 to 14.00 pH/±600.0 mV |
ORP mV | ±2000.0 mV | |
Ammonium- Nitrogen |
0.02 to 200 ppm (as N) | |
Chloride | 0.6 to 200 ppm | |
Nitrate-Nitrogen | 0.62 to 200 ppm (as N) | |
Conductivity | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) | |
TDS | 0 to 400000 mg/L or ppm (the maximum value depends on the TDS factor) | |
Resistivity | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm | |
Salinity | 0.00 to 70.00 PSU | |
Seawater σ | 0 to 50.0 st, s0, s15 | |
Turbidity | 0.0 to 99.9 FNU; 100 to 1000 FNU | |
Dissolved Oxygen | 0.0 to 500.0%; 0.00 to 50.00 ppm | |
Atm. Pressure | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa | |
Temperature | -5.00 to 55.00°C; 23.00 to 131.00°F; 268.15 to 328.15K | |
Resolution | pH/mV of pH input | 0.01 pH / 0.1 mV |
ORP mV | 0.1 mV | |
Ammonium- Nitrogen |
0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm | |
Chloride | 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm | |
Nitrate-Nitrogen | 0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm | |
Conductivity | manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm; automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; automatic mS/cm: 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm | |
TDS | manual: 1 mg/L (ppm); 0.001 g/L (ppt); 0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt); autorange scales: 1 mg/L (ppm) from 0 to 9999 mg/L (ppm); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); autorange g/L (ppt) scales: 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt); 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt); 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt) | |
Resistivity | dependent on resistivity reading | |
Salinity | 0.01 PSU | |
Seawater σ | 0.1 σt, σ0, σ15 | |
Turbidity | 0.1 FNU from 0.0 to 99.9 FNU; 1 FNU from 100 to 1000 FNU | |
Dissolved Oxygen | 0.1%; 0.01 ppm | |
Atm. Pressure | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa | |
Temperature | 0.01°C; 0.01°F; 0.01K | |
Accuracy @ 20°C | pH/mV of pH input | ±0.02 pH / ±0.5 mV |
ORP mV | ±1.0 mV | |
Ammonium- Nitrogen |
±5% of reading or 2 ppm, whichever is greater | |
Chloride | ±5% of reading or 2 ppm, whichever is greater | |
Nitrate-Nitrogen | ±5% of reading or 2 ppm, whichever is greater | |
Conductivity | ±1% of reading or ±1 µS/cm, whichever is greater | |
TDS | ±1% of reading or ±1 mg/L, whichever is greater | |
Salinity | ±2% of reading or ±0.01 PSU, whichever is greater | |
Seawater σ | ±1 σt, σ0, σ15 | |
Turbidity | ±0.3 FNU or ±2% of reading, whichever is greater | |
Dissolved Oxygen | 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading; 0.00 to 30.00 ppm: ±1.5% of reading or 0.10 ppm, whichever is greater; 30.00 ppm to 50.00 ppm: ±3% of reading | |
Atm. Pressure | ±3 mm Hg within ±15°C from the temperature during calibration | |
Temperature | ±0.15°C; ±0.27°F; ±0.15K | |
Temperature Compensation |
automatic from -5 to 55°C (23 to 131°F) | |
Logging Memory from Meter |
44,000 records | |
Logging Interval | 1 second to 3 hours | |
Computer Interface | USB (with HI 929829 software) | |
FastTracker™ TAG ID | yes | |
Waterproof Protection | IP67 | |
Environment | 0 to 50°C (32 to 122°F); RH 100% | |
Power Supply | 1.5V alkaline C cells (4) / 1.2V NiMH rechargeable C cells (4), USB, 12V power adapter | |
Dimensions | 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”) | |
Weight | 750g (26.5 oz.) |